phone Icon 1-866-653-2278 contact us Icon Contact Us favourite Icon MyList

FG-5750 StormMax

FG-5750 StormMax


The FG-5750 StormMax® storefront provides Level E hurricane protection for essential facilities through the use of insulating laminated glazing. The system is available with both dry and wet glazing options.

  • • Impact-resistant storefront system
    • Hurricane resistant
    • 2-1/2″ sight lines 5″ depth
    • 12′ Frame Height
    • Exterior or Interior Glazed Center Set
    • Pre-Glazed Option
    • 1-5/16″ Insulating Laminated Glazing


The FG-5750 system is an impact-resistant storefront system designed to accommodate 1-5/16" insulating impact glass. This system adheres to the highest safety standards, including ASTM Large Missile Level E for essential facilities, Florida’s High Velocity Hurricane Zone protocols, the Texas Department of Insurance product evaluations, and International Building Code. The system is unique in that it offers a dry glaze option for large and small missile impact. Access Florida Product Approval Evaluation Access Texas Department of Insurance Evaluation

• 2-1/2″ sight lines 5″ depth
• 12′ Frame Height
• Exterior or Interior Glazed Center Set
• Pre-Glazed Option
• 1-5/16″ Insulating Laminated Glazing
• Screw Spline Fabrication
• Dry or Wet Glazed Options
• 90 and 135 Degree Corner Mullion Options
• Enhanced Anchoring Options
• Aluminum Reinforcing Option
• Expansion Mullion
• High Performance Sill Receptor
• EZ Punch Capability
• Seamlessly integrates with MSD-375 StormMax® Entrances and Rugged StormMax® Entrances
• Factory finishes Kynar 500 Hylar 500
• Finishes meeting all provisions of AAMA 605.2-94 and AAMA 2805-98
• Factory anodized finishing

Show Less
Select File Type...
  • • Air Infiltration – Passed at 6.24 PSF per TAS 202 and ASTM E283
  • • Static Water – 15 PSF per TAS 202 and ASTM E331
  • • Structural Load – Tested up to +70 / -90 PSF per TAS 202 and ASTM E330
  • • Large Missile (ASTM E1996 Level D & E) & Small Missile (ASTM E1996 Level A) Impact and Cycling – Tested up to +70 / -90 PSF per TAS 201, TAS 203 and ASTM E1886/E1996
  • Approved for Essential Facilities in High Velocity Hurricane Zones (HVHZ)
  • • AAMA 501
  • • Florida Building Code TAS 201, TAS 202, TAS 203
  • • ASTM E283, E330, E331, E1886, E1996
  • • Large Missile (Level D & E) & Small Missile (Level A)
  • • Download Florida Product Approval Evaluations & Installation Instructions below (Access Level D documents on FPA website here / Access Level E documents on FPA website here)
  • • Download Texas Department of Insurance Evaluation below (Access Level D documents on TDI website here / TDI references FPS documents for Level E – Access Level E documents here)